Amerex Hirayama HV Series Portable, Top-Loading Autoclave
Couldn't load pickup availability
Got questions?
Feel free to get in touch
Amerex Hirayama HV Series Portable, Top-Loading Autoclave with Advanced Safety and User-Friendly Features
Manufacture Part No.(s) HV-25, HV-50, HV-85, HV-110
Features
- Space saving design with lid opening upward
- Programmable auto-start for initiating a cycle up to 1 week later
- Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C
- Automatic air purging by a microprocessor prevents over-pressurization during a cycle
- One-touch lever to easily open and close chamber lid
- Programmable rate of steam exhaust
- Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly
- In-process display shows status and progress of sterilization cycle
- Agar sterilization mode for sterilizing agar and then automatically maintaining it a liquid temperature
- Unique accessory: floating sensor to monitor load temperature
- Sterilization timer is activated only when load temperature reaches set temperature
- Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up
- Memory backup system retains user-programmed parameters even in case of power failure
- 1 Year Warranty
Specifications
Temperature Operating Range
- HV-25: 105°C to 126°C
- HV-50: 105°C to 135°C
- HV-85: 105°C to 135°C
- HV-110: 105°C to 135°C
Temperature Display Range
- HV-25: 128°C
- HV-50: 137°C
- HV-85: 137°C
- HV-110: 137°C
Temperature Warming Range
- 45°C to 60°C
Temperature Agar Dissolution
- Heating at 60°C to 100°C for up to 1 hour (temperature and time programmable), followed by 45°C to 60°C (programmable for up to 20 hours to prevent coagulation
Gauge Pressure Operating Range
- HV-25: 3 to 22 psi
- HV-50: 3 to 30 psi
- HV-85: 3 to 30 psi
- HV-110: 3 to 30 psi
Gauge Pressure Maximum Allowable
- HV-25: 27 psi
- HV-50: 38 psi
- HV-85: 38 psi
- HV-110: 38 psi
Timer Sterilization
- 1 to 250 minutes
Timer Delayed Auto-Start
- Program autoclave to start 1 minute to 7 days later
Dimensions Overall (W x D x H)
- HV-25: 19.0" x 18.0" x 37.4"
- HV-50: 20" x 21" x 41"
- HV-85: 26.0" x 25.6" x 39.4"
- HV-110: 26.0" x 25.6" x 46.5"
Chamber Dimensions (Diameter x Height)
- HV-25: 25 Liters, 9.4" x 21.6"
- HV-50: 50 Liters, 11.8" x 28.0"
- HV-85: 85 Liters, 16.5" x 24.2"
- HV-110: 110 Liters, 16.5" x 31.3"
Power
- HV-25: 120V, 50/60 Hz (220V/204V available)
- HV-50: 120V, 50/60 Hz (220V/240V available)
- HV-85: 208V/220V/240V. 50/60 Hz, single phase
- HV-110: 208V/220V/240V. 50/60 Hz, single phase
Programs
1. For Agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
2. For Liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable -> Completion
3. For Solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
4. For Melting Agar or for Faster Start-Up
Rapid Melting at 60°C to 100°C (temp and time programmable) -> Maintain at 45°C to 60°C (temp programmable) -> Completion
Safety Devices: Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker