Hillrom (Formerly Welch Allyn) Spot Vision Screener

SKU: VS100S-B-1
Regular price $8,327.85

Brand: Welch Allyn / Hillrom
SKU: VS100S-B
Condition: New
Availability: Current lead time is approximately 8-10 weeks
Shipping: Calculated at Checkout

Welch Allyn - Hillrom Promotion 2024: * :
Quantity:

Hillrom Welch Allyn Spot Vision Screener - VS100S-B (includes carry case)

Documents:

The Spot Vision Screener is a handheld vision screening device that helps users quickly and easily detect vision issues on patients from 6 months of age through adult. Spot screens both eyes at once from a nonthreatening 3-foot distance. The touch-screen display allows for 0ne-touch activation, simple management of patient data entry, and easy configuration for both vision screening tests and autorefraction applications.

FEATURES

  • Supports AAP screening guidelines for early detection of amblyopic risk factors
  • Easy to use, easy to implement with minimal user training required
  • Captures readings 97% of the time helping to screen otherwise difficult patients
  • Uses lights and sounds to help engage
  • Automated vision screening device provides thorough, objective, and easy-to-understand results
  • Adequately powered for mass screening events
  • Wireless printing and Wi-Fi enabled for easy export of data
  • Manual exports available via USB port

BATTERY LIFE

The VS100 Spot Vision Screener's battery will last over 4 hours on a single charge. Once the battery is fully depleted, recharging is 2 hours. There is no set number of screenings per charge for VS100 Spot Visions Screener, but the device is expected to operate for over 4 hours with continuous screening. The reason there is no set number of screenings is due to variation in the acquisition time of each subject.

CALIBRATION

The Spot vision Screener VS100 does not require annual device calibration. If a Calibration Certificate is requested for Spot Vision Screener, the device many be sent in for calibration.

ACCURATE DETECTION

Spot accurately detects the potential indication of these common vision problems:

  • Myopia (nearsightedness)
  • Hyperopia (farsightedness)
  • Astigmatism (blurred vision)
  • Anisometropia (unequal refractive power)
  • Strabismus (eye misalignment)
  • Anisocoria (unequal pupil size)
  • Accuracy refers to the sensitivity and specificity of the screening referral recommendation.

Evidence shows that using the Spot Vision Screener can help to dramatically reduce the time required to test vision over traditional screening tools. In one study, the Spot Vision Screener was used to test the vision of 537 elementary school students. Previous testing using a traditional screening tool took three days. With Spot, the entire population was screened in less than five hours. In addition, Spot captured definite results on 100% of the students, and 93 of them were referred for follow-up care with an eye care specialist.

One full year