HEINE NT4 Desktop Charger W/ Otoscope and Ophthalmoscope

SKU: A-XXX-XX-420-166
Regular price $1,354.28

Brand: Midmark Ritter
SKU: A-XXX-XX-420-166
Condition: New
Availability: Est. Lead Time 30 Business Days (As of 9/21/23)
Shipping: Calculated at Checkout

Choose Your Configuration and Model Number :
Quantity:

Midmark HEINE Diagnostic Instrument Desktop Charger Kits

Documentation:

An eye and ear examination is one of the most basic examinations a primary care provider performs during the visit. Even though it may seem like a simple task, there is more room for error than you might think. The type of instruments you use can have a direct impact on the quality of the exam and the accuracy of the diagnosis. A person must be able to observe anatomical structures clearly in order to detect any variations that may exist. Diagnostic instruments of the K180 series are equipped with Xenon-Halogen Illumination (XHL) that is capable of producing white light in truer colors with exceptionally high color rendering valu

K180® XHL OTOSCOPES AND OPHTHALMOSCOPES

OTOSCOPE - K180
With the aid of 3x magnification, more detail can be seen about anatomical structures and foreign bodies can be more easily seen.
In addition to providing homogeneous, bright illumination, fiber optic illumination also provides unobstructed views of the ear canal and tympanum.
Designed to prevent accidental loss or breakage, the swiveling view window is permanently attached to the instrument head and can be easily swiveled for use of the instrument and cleaning.

K180 OPHTHALMOSCOPE

Its precision HEINE spherical optics and proprietary glare-mitigating coatings offer crisp, clear images of the fundus at all times.
A dust-resistant design protects the sensitive optical components and ensures maintenance-free operation.
There are 27 different diopter settings with lenses ranging from -35D to +40D that will provide precisely focused images in all examining situations.
You have a choice between five types of apertures: large spot, small spot, red-free, fixation star and grid, and slit.

BETA® XHL OTOSCOPES AND OPHTHALMOSCOPES

LED High Quality Illumination
An even distribution of light across the entire field of view (including the edges) ensures that images are high-contrast, distortion-free, and have no distracting reflexes, shadows, or hot-spots.
In addition to this, our instruments have extremely high CRI values, with a CRI of greater than 97, a special index for red colors (R9: >93), and a color temperature of 3,500K.
LEDs help reduce costs and maintenance in the long run, as they have a life expectancy of approximately 100,000 hours and do not require any bulb changes.
Superior Optics
A superior aspherical optic deflects corneal reflections away from the examiner's path of vision, allowing for a crisper, clearer view of the fundus for an enhanced diagnostic experience. Using this process, you no longer have to deal with filters or other systems that reduce resolution and compromise your ability to see important details.
HEINE technology delivers an exclusive 4.2x magnification for more detail of anatomical structures and easier identification of foreign bodies.
This lens offers a remarkable depth of field and a sharp spatial image in a convenient working range with a large field of view.
Dust-proof Design
Featuring a unique dust-proof design, precision optical components are protected against dust and ensure maintenance-free operation.

Midmark HEINE® Diagnostic Instruments Limited Warranty SCOPE OF WARRANTY Midmark Corporation ("Midmark") warrants to the original retail purchaser that it will, at Midmark’s option, repair or replace diagnostic instruments manufactured by HEINE and sold by Midmark (except for those not warranted under "Exclusions") that are defective in material or workmanship under normal use and service. The sole remedy under this limited warranty is the repair or replacement, at Midmark's option, of the applicable components. This limited warranty shall only apply to defects that are reported to Midmark within the applicable warranty period and which are determined to exist upon examination by Midmark. This warranty extends only to the original retail purchaser of a product and is not transferable or assignable. Replacement components or products may be used and/or refurbished components or products, provided they are of like quality and specifications as new components or products. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of invoice to the original retail purchaser of the product shall be as follows: (1) Ten (10) years for Diagnostic instruments (other than GAMMA G5 Sphygmomanometers) manufactured by HEINE and sold by Midmark; (2) Five (5) years for GAMMA G5 Sphygmomanometers manufactured by HEINE and sold by Midmark; and (3) Twelve (12) months on parts and labor. OBTAINING WARRANTY SERVICE Warranty service must be obtained through Midmark. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark. com; by phone at 1.844.856.1230, option 3 or by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380. It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser’s expense. It is also the retail purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this limited warranty. EXCLUSIONS: This limited warranty does not cover and Midmark shall not be liable for the following: (1) Defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, negligent storage, tampering or failure to seek and obtain repair or replacement in a timely manner; (2) Products which are not installed, used, and properly cleaned and maintained as required or recommended in the Midmark "Installation" and/ or "Installation/Operation Manual" for the applicable product, including the specified structural and operational environmental conditions and electrical requirements; (3) Normal wear and tear (4) Fire or theft (5) Products considered to be single-use items or consumables (e.g. bulbs, cuffs, and batteries) (6) Rechargeable batteries and batteries (7) Use of non-original HEINE spare parts (8) Exposed and accessible control and supply cables with corresponding plug connection (9) Charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark; (10) Costs and expenses of routine maintenance and cleaning; (11) Representations and warranties made by any person or entity other than Midmark. (12) Custom manufactured products; (13) Alterations or modifications to the product by any person or entity other than Midmark; and (14) Products that would otherwise by covered under this limited warranty, but are acquired: (i) from a person or entity that is not Midmark or one of its authorized dealers; or (ii) from a Midmark dealer that is not authorized to sell the product at issue in the geographic territory where the purchaser is located, or is not authorized to sell the product at issue within the medical market